EWP115 NYLON COMBO - 12V 115LPM/30GPM REMOTE ELECTRIC WATER PUMP & CONTROLLER CO

Take total control of your engine cooling with the Davies Craig EWP®115 Nylon Electric Water Pump and LCD EWP®/Fan Digital Controller. The Controller will also
manage the operation of your Thermatic® Fan. The EWP®115 (115 litres per minute) pump is suitable for small, medium, large, high-performance and 4WD vehicles. It’s a performance product  that improves engine cooling control and
capacity whilst giving you more power and torque and improved fuel economy.

 

 


The EWP®115 and LCD EWP®/Fan Digital Controller Combo Pack is the most economical way to increase horsepower and save on fuel consumption whilst caring for your engine.


The Davies, Craig EWP® header adaptor kit can replace the mechanical water pump completely. (See EWP Header Adaptors on website)


The world’s most advanced total engine cooling management

 universal fit

 more power

 more cooling

 increase fuel efficiency

 extend engine life

 world-leading technology

 lightweight Nylon   

 

EWP® INSTALLATION OPTIONS

Installing an EWP® as an AUXILIARY PUMP

  • Leaving the mechanical water pump in place, install the EWP® into the bottom radiator hose.
  • Remove the thermostat and drill two approx. 3mm (1/8") holes in the thermostat plate to allow some coolant circulation when the thermostat is closed. Re-install ensuring that the thermostat housing is clean and a new gasket is used if required.

EWP® INSTALLATION – disabling Mechanical water pump

  • Leaving the mechanical water pump in place, install the EWP® into the bottom radiator hose and remove the manufacturer’s thermostat.
  • You will need to bypass the water pump pulley by installing an appropriate length belt (not supplied). This method makes for an easy installation.
  • If running the pump continuously remove the thermostat and drill two approx. 3mm (1/8") holes in the thermostat plate to allow some coolant circulation. Re-install ensuring that the thermostat housing is clean and a new gasket is used if required.

In both these cases, the EWP® will pump past the impeller of the mechanical water pump.

Disengaged mechanical water pump (recommended)

  • Remove the mechanical water pump and remove the thermostat.
  • Then remove the impeller from the mechanical pump shaft. Retain the mechanical water pump using the pump pulley as an idler to avoid re-routing the drive belt.
  • Block any bypass passages and re-install the disengaged water pump ensuring that all gasket surfaces are clean and the new gaskets are properly fitted to prevent leaks.
  • Install the EWPÒ into the bottom radiator hose.

Removed mechanical water pump (Ideal)

  • Remove the mechanical water pump and thermostat from the engine.
  • Install a Davies Craig EWP® Header Adaptor or blanking plate (not supplied). Ensuring the gasket surfaces are clean and the appropriate gasket or sealant is used to prevent leaks.
  • Install the EWP® into the bottom radiator hose. This method will require you to modify or replace the standard radiator hose.
  • Install an appropriate length belt (not supplied) to drive the accessories.

In most cases EWP® will be adequately supported by the radiator hose. Where mounting is required, the EWP® must be soft mounted to protect against vibration. For the EWP115, EWP130 and EWP150 Part #8700 Mounting bracket is recommended.

   

LCD EWP & FAN DIGITAL CONTROLLER - 12 & 24 VOLT 
This LCD EWP® / Fan Digital Controller (Part #8002) is Australian designed and as part of this Australian manufacturing company’s continuous improvement program this advanced Digital Controller boasts a suite of enhancements. 

  

The updated LCD Digital Controller how has two specific functions. This unique Controller will now manage the operation of the EWP® by varying the speed of the EWP® in response to the temperature of the engine and manage control of your electric engine fan. The Controller has a push-button on the facia panel that offers target temperatures Singular degrees from 60°C (140°F) to 100°C (212°F). 

Generally, higher engine temperature will offer improved fuel efficiency and lower engine temperature more power. The LCD Digital Controller will now operate the engine’s electric fan automatically once the engine has reached +3c above the target temperature. A significant benefit too is the Controller allows the EWP® to run on after ignition shutdown to reduce heat soak. It is recommended that engine operational temperatures be checked with manufacturer. 

Features
  Black & White Numerical Screen
 Celsius or Fahrenheit display option
 Warning Alarms: 

- Plus 10°C (14°F) set/target temperature
- Under temp 40°C after 5 mins
- Temp sensor error
- Over or under voltage
- EWP error

   Select any set temp range from 40°C (104°F)to 110°C (230°F)
 Set / targeted temperature memory
 Override feature to assist bleeding EWP & fail safe
 Input voltage display
 Compatible with billeted style Electric Water Pumps

EWP115 NYLON COMBO - 12V 115LPM/30GPM REMOTE ELECTRIC WATER PUMP & CONTROLLER CO

SKU: 8930
£261.68Price
Kit Contents

EWP COMPONENTS

 HARDWARE BAG COMPONENTS

Description 

Qty 

Description

Qty

EWP115 Nylon Short Kit

1

Scotch Lock

1

EWP & FAN LCD Controller

1

Ring Terminal

1

Inline Adaptor

1

Ring Terminal (Yellow)

1

Wiring Harness (10A Fuse)

1

Self Tap Screws

1

Thin Rubber Sleeves

4

Temp Sensor Assembly

1

Hose Clamps

4

 Mount Pad Hook & Loop 1

EWP Hardware Bag

1

   

  

Technical Specifications
Technical Specifications - EWP115      Technical Specification - LCD Controller
Operating voltage 3V DC to 15V DC Voltage range 12V DC to 29V DC
Maximum current 10A @ 13V Display LCD size

64.6mm (2.54”) x 55.6mm (2.19”)

Flow rate (max) 115 L/min (30.38 US gal/min) @ 13V DC Maximum current 12Amps
Operating temp. -40° to 130°C (-40° to 266°F) Warning alarm High & low Temp., Above set temp., Sensor short circuit, Pump error, High & low voltage and Sensor open circuit
Pump design

Clockwise centrifugal with volute chamber

Targeted (set) temperatures Singular degrees from:
40°C (104°F) to 110°C (230°F)
Pump weight 920 grams (2.3 lb) Memory Set & targeted temperature
Pump material Nylon 66, 30% glass-filled Fan cut-in temp. 3°C (5.4°F) above the targeted (set) temperature
Burst pressure 500 kPa (72.5 psi) Controller type PCB with micro-processor
Seal Ceramic face seal Sensor type Thermister in housing
Self Priming No, none of our pumps are self-priming
Fits hose sizes 35mm to 51mm (1.38” to 2”) Overrun/ shutdown -10°C (14°F) below set/target temperature or 3 minutes
 Push-On fitting Size  

EWP Inlet & Outlet 38mm

with 3mm Sleeve (#8510) 44mm

with 6mm Sleeve (#8511) 51mm 

Indicators Temperature, power, EWP, test, fan, high & low temp, voltage, above set temperature (with alarm)
Weight 100 grams (3.5 oz)
Dimensions

Length = 98mm (3.8")

Width = 95mm (3.7")

Depth = 25mm (1”)